Legionella Industrial Test Kit

Industrial Test Instruction Diagram
Industrial test kit instruction diagram

The Industrial Legionella Test™, is a breakthrough technology from hydrosense® for the rapid detection of Legionella bacteria in water – delivering test results in minutes instead of days. View our instruction video or Download data sheet (pdf)

The test kit contains all the items required to perform 5 tests – including filters, recovery buffer, collection vessel and sample point.

  • These tests are optimised for use with industrial water systems, cooling towers and whirlpool spas.
  • This filtration step needs no pumping, just connect the sample point to the water system and use the system pressure to drive the filtration.
  • Single use hollow fibre filtration modules.
  • Pre-filled syringe containing recovery buffer, no need to measure or dilute solutions.
  • The test is simple to use and fast, with no interpretation required.
  • Results are easy to read and obtained within 30 to 35 minutes.
  • The test allows immediate understanding and response to the water conditions.
  • Use can reduce risk of outbreaks and litigation.
  • Regular use will increase confidence in your Legionella control.

The hydrosense® Legionella Field Test uses an immunochromatographic assay, to detect the presence of cell surface antigens from Legionella bacteria in a sample. The presence of antigen causes the "Test Line" to turn red in colour. A "Control Line"is included which should always turn red if the test has been performed correctly.

Product details

Bacteria detected Legionella pneumophila serogroup 1
Detection method Lateral flow immunochromatographic assay
Lower limit of detection Up to 100 CFU/L (0.1 CFU/mL)
Specificity Tested against a wide range of waterborne bacteria, including Acinetobacter calcoaceticus, Aeromonas hydrophila subsp. hydrophila, Bacillus subtilis, Burkholderia cepacia, Citrobacter freudii, Citrobacter koseri, Escherichia coli, Enterobacter cloacae, Klebsiella oxytoca, Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas putida, Pseudomonas stutzeri, Ralstonia pickettii, Raoultella terrigena, Streptococcus pyrogenes, Yersinia ruckeri. No cross reactions observed at concentrations <= 10^9 CFU/L. Staphylococcus aureus has been observed to cross react with the test at concentrations > 10^8 CFU/L. Legionella pneumophila serogroups 4 & 7 cross react with the test at concentrations >10^9 CFU/sample. The test does not react with any other L. pneumophila serogroups or L. species tested.
Test volume 100 μL
Suggested sample volume 250 mL
Sample parameters Sample should filter in less than 10 minutes.
Biocides The product has been tested with a range of common biocides and biodispersants used in Legionella control, at their normal maximum operating concentration. Active ingredients tested include: glutaraldehyde, didecyl-dimethyl-ammonium chloride, isolthazoles, dibromonitrilopropionamide, ionic and non-ionic surfactants. The test gives a false positive if used with polymeric biguanide or THPS.
Operator time 5 - 10 minutes
Development time 25 minutes
Sample point Supplied with both ½” and ¾” female threaded fittings, additional sample points are available (part no. 100171)
Shelf life 18 months from manufacture when stored at room temperature (<30°C) in original packaging.

Enquire or Buy